 PRODUCT SPECIFICATIONS AVC Liquid Crystal Displays Group
LS037V7DW01
TFT-LCD Module
Spec. Issue Date: May 17, 2006 No: LCP-06008A
LCP-06008A-1
NOTICE This publication is the proprietary of SHARP and is copyrighted, with all rights reserved. Under the copyright laws, no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical for any purpose, in whole or in part, without the express written permission of SHARP. Express written permission is also required before any use of this publication may be made by a third party. The application circuit examples in this publication are provided to explain the representative applications of SHARP's devices and are not intended to guarantee any circuit design or permit any industrial property right or other rights to be executed. SHARP takes no responsibility for any problems related to any industrial property right or a third party resulting from the use of SHARP's devices, except for those resulting directly from device manufacturing processes. In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP's device. SHARP reserves the right to make changes in the specifications, characteristics, data, materials, structures and other contents described herein at any time without notice in order to improve design or reliability. Contact SHARP in order to obtain the latest specification sheets before using any SHARP's device. Manufacturing locations are also subject to change without notice. Observe the following points when using any device in this publication. SHARP takes no responsibility for damage caused by improper use of the devices. The devices in this publication are designed for use in general electronic equipment designs, such as: Personal computers Office automation Telecommunication equipment Industrial control Consumer electronics Test and measurement equipment Audio visual and multimedia equipment
The appropriate design measures should be taken to ensure reliability and safety when SHARP's devices are used for equipment such as: Transportation control and safety equipment(i.e., aircraft, trains, automobiles, etc.) Traffic signals Alarm equipment Gas leakage sensor breakers Various safety devices etc.
SHARP's devices shall not be used for equipment that requires extremely high level of reliability, such as: Military and space applications Medical equipment for life support Contact a SHARP representative, in advance, when intending to use SHARP's devices for any "specific" applications other than those recommended by SHARP. Contact and consult with a SHARP representative if there are any questions about the contents of this publication. Nuclear power control equipment
LCP-06008A-2
(1) Application This literature applies to LS037V7DW01. (2) Overview This module is a color transflective and active matrix LCD module incorporating CG-Silicon TFT (Continuous Grain-Silicon Thin Film Transistor). It is composed of a color TFT-LCD panel, driver ICs (with control Function), an FPC(with DC-DC Converter), a back light, a touch panel and a back sealed casing. It is composed control circuit. Graphics and texts can be displayed on a 480x3x640 dots panel with 262,144 colors by supplying. This LCD module has multi resolution and multi colors functions. A resolution mode is selective in VGA (480Hx640V) or QVGA (240Hx320V). A Color mode is selective in 262,144 colors (18bit RGB) or 8 colors (3bit RGB). It is a wide viewing-angle-mode (Vertical viewing angle:(80) Horizontal viewing angle: (80) ,CR5). (3) Mechanical specifications Table 1 Parameter Screen size (Diagonal) Display active area Touch panel active area Pixel format Dot pitch Pixel configuration Display mode Unit outline dimension Mass Surface hardness Specifications 9.4 [3.7"] Diagonal 56.16Hx74.88V 57.4Hx76.1V 480(H)x640(V) (1 pixel = R+G+B dots) 0.039Hx0.117V R,G,B vertical stripe Normally Black 65.0(W)x89.2(H)x4.4(D) 3H mm Note3-1 Units cm mm mm pixels mm Remarks
Note 3-1Excluding protrusion. For detailed measurements and tolerances, please refer to Fig. 1. (4) Pixel configuration
(1,1)
(m,1)
RGB
1
LCD/LED/TP FPC
51
(1,n)
Display area
VGA mode m=480,n=640 QVGA modem=240,n=320
(m,n)
LCP-06008A-3
(5) Input/Output terminal 5-1) TFT-LCD panel and Backlight driving section Table2 Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Symbol LED+ NC LED T4 T3 T2 T1 GND RESB GND MO UD LR INI DEN GND VSYNC GND HSYNC GND CLKIN GND VCC VCC VCC GND B5 B4 B3 B2 B1 B0 GND G5 G4 I/O I I I I I I I I I I I I I I I I I Touch panel lower electrode(Right side) Touch panel upper electrode(6 o'clock side) Touch panel lower electrode(Left side) Touch panel upper electrode(12 o'clock side) Ground Reset signal Ground Selection for resolution(VGA/QVGA) Selection for vertical scanning direction Selection for horizontal scanning direction Power on control Data enable signal Ground Vertical synchronizing signal Ground Horizontal synchronizing signal Ground System clock signal Ground Power supply(3.3V) Power supply(3.3V) Power supply(3.3V) Ground Blue data signal(MSB) Blue data signal Blue data signal Blue data signal Blue data signal Blue data signal(LSB) Ground Green data signal(MSB) Green data signal Note5-2 Note5-2 Note5-2 Note5-3 Note5-4 Note5-5 Note5-2 Note5-6 Note5-2 LED power supply(Low Voltage) Description LED power supply(High Voltage) Remarks Note5-1
LCP-06008A-4
Pin No. 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 Symbol G3 G2 G1 G0 GND R5 R4 R3 R2 R1 R0 GND SMPSYNC SMPDATA ID1 I/O I I I I I I I I I I I I Green data signal Green data signal Green data signal Green data signal(LSB) Ground Red data signal(MSB) Red data signal Red data signal Red data signal Red data signal Red data signal(LSB) Ground Selection for Vertical/ Horizontal synchronizing signal timing(clock timing) Selection for Red, Green and Blue data signal timing (clock timing) Ground Note5-7 Note5-7 Description Remarks
Note5-1When superfluous current flows,please intercept current with a fuse etc. Note5-2See section(7-1)-(A) "Cautions when you turn on or off the power supply". Note5-3 Selection for resolution mode MO Low High Resolution VGA(480RGBx640) QVGA(240RGBx320)
Note5-4Selection for vertical scanning direction U/L High Low Scanning direction (Pixel configuration) Conventional scanning ( X , 1 ) (X,Y) Inverted scanning ( X , 1) ( X , Y) VGA mode: Y=640, QVGA mode: Y=320 Note5-5Selection for horizontal scanning direction LBR High Low Scanning direction (Pixel configuration) Conventional scanning (1,Y) (X,Y) Inverted scanning (1,Y) (X,Y) VGA mode: X=480, QVGA mode: X=240 Note5-6 DEN makes it possible to take effective data timing. Horizontal Data Sampling Timing is shown in 7-2) Timing Characteristics of input signals.
LCP-06008A-5
Note5-7Selection for synchronizing signal and data signal timing(clock timing)
SMPSYNC Selection for Vertical/ Horizontal synchronizing signal timing(clock timing) SMPDATA
Selection for Red,Green and Blue data signal timing(clock timing)
High Low
Rise edge of clock(CLKIN) Fall edge of clock(CLKIN)
High Low
Rise edge of clock(CLKIN) Fall edge of clock(CLKIN)
(6)Absolute Maximum Ratings Table 3 Parameter Power supply (COG driver / Digital) Input voltage (Digital) Touch panel input voltage Operating temperature(Panel surface) Storage temperature LED current Symbol VSHD VID VIT opp stg IL
Condition
Ratings -0.3+4.0 -0.3VSHD+0.3 7.0 -1060 -2070 30
Unit V V V mA
Remark [Terminal] Note6-1 Note6-2 Note6-2 Note6-3
Ta=25 Ta=25 Ta=25 Ta=25
[Terminal] INI,VSYNC,HSYNC,MO,UD,LR,CLK,R0R5,G0G5,B0B5,DEN,RESB Note6-1Applies to Touch panel input terminal.(xL,xR,yU,yD) Note6-2Humidity: 95%RH Max.(at Ta 40). Maximum wet-bulb temperature is less than 39 (at Ta > 40). Condensation of dew must be avoided. Note6-3( Provisional plan) LED current should be as per below figure.
Ambient Temperature vs. LED Current 35 30 LED current[mA] 25 20 15 10 5 0 0 10 20 30 40 50 60 Ambient temperature[] 70
(7)Electrical characteristics 7-1) Recommended operating conditions A) TFT-LCD panel driving section Table4 Parameter Supply voltage for COG driver Input voltage (Low) Input voltage (High) Input current (Low) Symbol Digital VSHD VILS VIHS IILS Min. +3.0 GND 0.8VSHD Typ. +3.3 Max. +3.6 0.2VSHD VSHD 10 Unit V V V Note 7-1 Note 7-1 GND=0V Remarks
A Note 7-1
LCP-06008A-6
Cautions when you turn on or off the power supply
ON sequence 2Vsync
CLKIN,VSYNC,HSYNC RGB data Signal RESB INI(Power on Control) VCC
(External power Supply 3.3V)
Conventional Operation
OFF sequence 5Vsync 2Vsync
GND GND
Conventional Operation Conventional Operation Min20sec Width
GND GND GND GND
GND GND
(1) After VCC is ON ,please make sure to start HVIF(CLK,HSYNC,VSYNC,RGB data signal) synchronized signal before INI(Power on control) becomes High. (2) Please keep HVIF(CLK,HSYNC,VSYNC,RGB data signal) synchronized signal High for more than 5 vertical period after INI becomes Low to shut down VCC. (3) Stabilize VCC(3.3V) within double vertical periods. (4) VCC is stabilized to GND within double vertical periods. (5) When the power supply is on again after Power Supply Off sequence ,please put the RESB signal before Power Supply On sequence. RESB signal needs LOW level more than 20sec after VCC(+3.3V) ON. (6) Please Set RESB signal before INI Signal. Note 7-1INI,VSYNC,HSYNC,MO,UD,LR,CLK,R0R5,G0G5,B0B5,DEN,RESB terminals are applied. Each voltage should be kept to satisfy absolute maximum ratings. If the applied voltage goes beyond absolute maximum ratings, the LCD module may be broken eternally. B) Back light driving section Ta=25 Parameter LED voltage(VL) LED current(IL) Power consumption Symbol VL IL WL MIN TYP 27.9 16 446.4 MAX 31.5 20 630 Units V mA mW Note 7-3 Remarks terminal Note 7-2
Table 5
Note 7-2VL(TYP) at IL(16mA). VL (MAX) at IL (20mA). Note 7-3Calculated reference value. WL=(VLxIL)
LCP-06008A-7
7-2) Timing Characteristics of input signals Table 6 Parameter CLK Period CLK Low Width CLK High Width Data setup time Data hold time Pulse width of DEN Period of HSYNC Pulse width of HSYNC HSYNC setup time HSYNC hold time Horizontal Back Porch Horizontal Front Porch Period of VSYNC Period of VSYNC Pulse width of VSYNC VSYNC setup time VSYNC hold time VSYNC-HSYNC phase difference
Input Signal 1 Rising Time Input Signal 1 Falling Time Input Signal 2 Rising Time Input Signal 2 Falling Time
AC Characteristics Symbol tCLK tCLKL tCLKH tDS tDH tHHW tHS thsw tHSYS tHSYH tHBP tHFP tVS tVS tvsw tVSYS tVSYH tVHD tRISE1 tFALL1 tRISE2 tFALL2 tRESW VGA QVGA VGA QVGA VGA QVGA VGA QVGA VGA QVGA MODE VGA QVGA Min. 38 152 15 15 10 10 10 10 28 14 0 0 57 10 10 0 20 Typ. 39.7 158.8 480 240 648 324 2 78 38 88 44 59.94 648 324 1 Max. 41.7 167 166 82 138 68 63 HCYC-2 5 5 5 5 CLK CLK ns ns CLK CLK Hz HCYC HCYC ns ns CLK ns ns s s s Note 7-4 Note 7-5 Note 7-5 Note 7-6 Note 7-6 Note 7-7 VSYNC HSYNC Unit ns ns ns ns ns R0R5, G0G5, B0B5 CLK Note
Reset Pulse Width
LCP-06008A-8
Note 7-4HCYC = HSYNC Period(VGA:Typ.648CLK, QVGA:Typ.324CLK) Note 7-5VSYNC,HSYNC,CLK,R0R5,G0G5,B0B5,DEN terminals are applied.
tRISE1 Input Signal 0.9VDD 0.1VDD
tFALL1 0.9VDD 0.1VDD
Fig 7-1 Input Signal Rising/Falling Timing
Note 7-6INI,RESB terminals are applied.
tRISE2 Input Signal 0.9VDD 0.1VDD
tFALL2 0.9VDD 0.1VDD
Fig 7-2 Input Signal Rising/Falling Timing
Note 7-7Reset Signal Timing chart
tRESW RESB
Fig 7-3 Reset Timing Signal
7-3)Power consumption Measurement condition : Vsync=59.94Hz,Hsync=38.84kHz,CLK=25.17MHz,Ta=25 (VGA Mode) Table 7 Parameter VSHD Total(Digital+Analog) Note 7-8White Pattern Sym ISHD Conditions VSHD=+3.3V MIN 45 (when conventional scan mode) TYP MAX 75 Unit mA Remarks Note7-8
LCP-06008A-9
[Portrait VGA Mode Timing Chart]
[Vertical Timing]
tvs(Typ.648) VSTyp.648H
VSYNC
tvsw
648 1 2 3 4 641 642 643 644
HSYNC
645
646
647
648
1
2
3
CLKIN RIN[5:0] GIN[5:0] BIN[5:0]
1LINE
2LINE
639LINE 640LINE
1LINE
[Horizontal Timing]
HS(Typ.648CLK
HSYNC
tHSW
tHBP
tHHW
tHFP
DEN
CLK RIN[5:0] GIN[5:0] BIN[5:0]
1
2
3
4
477
478
479
480

tVSYS VSYNC tVSYH
tCLK tCLKL CLK
tVHD tHSYS tHSYH
tCLKH
HSYNC
tDS RIN[5:0] GIN[5:0] BIN[5:0]
tDH
CLKIN
Fig 7-3 LCDIF signal timing in Portrait VGA mode
LCP-06008A-10
[Portrait QVGA Mode Timing Chart]
[Vertical Timing]
tVS(Typ.324) Typ.324H
VSYNC
tVSW
HSYNC
324
1
2
3
4
321
322
323
324
1
2
3
CLKIN RIN[5:0] GIN[5:0] BIN[5:0]
1LINE
2LINE
319LINE 320LINE
1LINE
[Horizontal Timing] HSYNC
HSTyp.324CLK
tHBP tHSW
tHHW
tHFP
DEN
CLK RIN[5:0] GIN[5:0] BIN[5:0] 1
2
3
4
237
238
239
240
tVSYS VSYNC tVSYH
tCLK tCLKL CLK
tVHD tHSYS tHSYH
tCLKH
HSYNC
tDS RIN[5:0] GIN[5:0] BIN[5:0]
tDH
CLKIN
Fig 7-4 LCDIF signal timing in Portrait QVGA mode
LCP-06008A-11
() Input Signals, Basic Display Color and Gray Scale of Each Color Table 8 Colors & Gray scale Gray Scale R0 Black Blue Green Cyan Red Magenta Yellow White Black Gray Scale of red Gray Scale of green Gray Scale of bleu Darker Basic color GS0 GS1 GS2 0 0 0 0 1 1 1 1 0 1 0 R1 0 0 0 0 1 1 1 1 0 0 1 R2 0 0 0 0 1 1 1 1 0 0 0 R3 0 0 0 0 1 1 1 1 0 0 0 R4 0 0 0 0 1 1 1 1 0 0 0 R5 0 0 0 0 1 1 1 1 0 0 0 G0 0 0 1 1 0 0 1 1 0 0 0 18bit RGB color display mode Data signal G1 0 0 1 1 0 0 1 1 0 0 0 G2 0 0 1 1 0 0 1 1 0 0 0 G3 0 0 1 1 0 0 1 1 0 0 0 G4 0 0 1 1 0 0 1 1 0 0 0 G5 0 0 1 1 0 0 1 1 0 0 0 B0 0 1 0 1 0 1 0 1 0 0 0 B1 0 1 0 1 0 1 0 1 0 0 0 B2 0 1 0 1 0 1 0 1 0 0 0 B3 0 1 0 1 0 1 0 1 0 0 0 B4 0 1 0 1 0 1 0 1 0 0 0 B5 0 1 0 1 0 1 0 1 0 0 0
Brighter Red Black Darker
GS61 GS62 GS63 GS0 GS1 GS2
1 0 1 0 0 0
0 1 1 0 0 0
1 1 1 0 0 0
1 1 1 0 0 0
1 1 1 0 0 0
1 1 1 0 0 0
0 0 0 0 1 0
0 0 0 0 0 1
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
Brighter Green Black Darker
GS61 GS62 GS63 GS0 GS1 GS2
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
1 0 1 0 0 0
0 1 1 0 0 0
1 1 1 0 0 0
1 1 1 0 0 0
1 1 1 0 0 0
1 1 1 0 0 0
0 0 0 0 1 0
0 0 0 0 0 1
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
Brighter Bleu
GS61 GS62 GS63
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
1 0 1
0 1 1
1 1 1
1 1 1
1 1 1
1 1 1
0 : Low level voltage
1 : High level voltage
Each basic color can be displayed in 64 gray scales from 6 bit data signals. According to the combination of total 18 bit data signals, the 262,144-color display can be achieved on the screen.
LCP-06008A-12
(9)Optical characteristics 9-1) Not driving the Back light condition Table 9 Parameter Viewing angle range Contrast ratio Response Rise time Fall Symbol 21,22 11, 12 CRmax r d x y Reflection ratio R =0 =0 CR1.2 =0 Condition Min 30 30 Typ 40 40 Max Unit degree degree [Note 9-2,4] ms ms [Note 9-3] Ta=25C Remarks [Note 9-1,2]
20 20 0.35 0.40
0.25 0.30 2
2
10 10 0.30 0.35 4
White chromaticity
[Note 9-4] % [Note 9-5]
-
* The measuring method of the optical characteristics is shown by the following figure. * A measurement device is Otsuka luminance meter LCD5200.(With the diffusion reflection unit.)
Normal line Photodetector (with luminosity correction system) Chemical coated surface (Optical diffusion treatment)
A diffusion beam
A diffusion beam
A beam (through an optical fiber) Touch panel Module
Center of display
Measuring method (a) for optical characteristics
LCP-06008A-13
9-2) Driving the Back light condition Ta=25C Parameter Viewing angle range Contrast ratio Response Rise time Fall Symbol 21,22 11,12 Crmax r d x y S Y U = 0 = 0 = 0 Condition CR5 Min 40 40 100 Typ 80 80 200 15 20 0.31 0.33 35 165 Max Unit degree degree Remarks [Note 9-1,2,6] [Note 9-2] ms ms [Note 9-3]
Table 10
20 30 0.36 0.38
0.26 0.28
White chromaticity NTSC ratio Brightness Uniformity
110 60
-
% cd/m2 % IL=16mA [Note 9-7]
-
* The measuring method of the optical characteristics is shown by the following figure. * A measurement device is TOPCON luminance meter SR-3.(Viewing cone 1)
Photodetector(including luminosity facter)
Touch panel LCD module
Center
Measuring method for optical characteristics
LCP-06008A-14
Note 9-1Viewing angle range is defined as follows.
22 11
Normal Line 12 21
Definition for viewing angle Note 9-2Definition of contrast ratio: The contrast ratio is defined as follows: Contrast ratio(CR) = Photodetecter output with all pixels white(GS63) Photodetecter output with all pixels black(GS0) VCOMAC=5.0Vp-p Note 9-3Definition of response time: The response time is defined as the following figure and shall be measured by switching the input signal for "black" and "white".
Black
White
Black
100% 90% Photodetecter output (arbitrary unit) 10% 0% r
Time
d
Note 9-4A measurement device is Minolta CM-2002. Note 9-5Definition of reflection ratio Reflection ratio =
Light detected level of the reflection by the LCD module
Light detected level of the reflection by the standard white board
Note 9-6A measurement device is ELDIM EZContrast
LCP-06008A-15
Note 9-7Definition of Uniformity Minimum Brightness Maximum Brightness
1/6 1/6
Uniformity =
x100(%)
The brightness should be measured on the 9-point as shown in the right figure.
(10)Display quality The display quality of the color TFT-LCD module shall be in compliance with the Incoming Inspection Standards TFT-LCD. (11)Touch panel characteristics Table 11 Parameter Input voltage Resistor between terminals(X1-X2) Resistor between terminals(Y1-Y2) Line linearity(X direction) Line linearity(Y direction) Insuration resistance Minimum tension for detecting (12)Mechanical characteristics 12-1) External appearance See Fig. 1 Outline Dimension 12-2) FPC (for LCD panel) characteristics Specific connector LCD-FPC : HIROSE FH23-51S-0.3SHAW(05) (Bottom contact only) Min. 200 200 20 Typ. 5.0 Max. 7.0 650 640 1.5 1.5 0.79 Unit V % % M N DC25V 1min Remark
LCP-06008A-16
(13)Design guidance for touchpanel(T/P) (1) If an consumer will put a palm on housing in normal usage, care should be taken as follows. (2) Keep the gap, for example 0.3 to 0.7mm,between bezel edge and T/P surface. The reason is to avoid the bezel edge from contacting T/P surface that may cause a "short" with bottom layer(See Fig.2) (3) Insertion a cushion material is recommended. (4) The cushion material should be limited just on the busbar insulation paste area. If it is over the transparent insulation paste area, a "short" may be occurred. (5) There is one where a resistance film is left in the T/P part of the end of the pole. Design to keep insulation from the perimeter to prevent from mis-operation and so on.
Housing Cushion material PET Film Insulation metal Transparent Insulation Paste Glass Prohibition Area Fig.2 Key Area 0.3 0.7mm Electrode Layer
LCP-06008A-17
(14)Handling Precautions 14-1) Insertion and taking out of FPCs (1) Be sure insert and take out of the FPC into the connector of the set after turning off the power supply on the set side. 14-2) Handling of FPCs (1) The FPC for LCD panel shall be bent only slit portion. The bending slit shall be bent uniformly on the whole slit portion with bending radius larger than 1.0mm ,and only inner side (back side of the module). Don't bend it outer side (display surface side). (2) Don't give the FPCs too large force, for example, hanging the module with holding FPC. Moreover, Do not put stress on the components mounted on FPC to avoid failure of the components. 14-3) Installation of the module (1) On mounting the module, be sure to fix the module on the same plane. Taking care not to warp or twist the module. 14-4)Precaution when mounting (1) If water droplets and oil attaches to it for a long time, discoloration and staining occurs. Wipe them off immediately. (2) Glass is used for the TFT-LCD panel or touch panel. If it is dropped or bumped against a hard object, it may be broken. Handle it with sufficient care. (3) As the CMOS IC is used in this module, pay attention to static electricity when handling it. Take a measure for grounding on the human body. 14-5)Others (1) The liquid-crystal is deteriorated by ultraviolet rays. Do not leave it in direct sunlight and strong ultraviolet rays for many hours. (2) If it is kept at a temperature below the rated storage temperature, it becomes coagulated and the panel may be broken. Also, if it is kept at a temperature above the rated storage temperature, it becomes isotropic liquid and does not return to its original state. Therefore, it is desirable to keep it at room temperature as much as possible. (3) If the LCD breaks, don't put internal liquid crystal into the mouth. When the liquid crystal sticks to the hands, feet and clothes, wash it out immediately. (4) Wipe off water drop or finger grease immediately. Long contact with water may cause discoloration or spots. (5) Observe general precautions for all electronic components. (6) Static image should not be displayed more than 5 minutes in order to prevent from occurrence of residual image.
LCP-06008A-18
(15)Reliability Test Conditions for TFT-LCD Module Table 12 No. 1 2 3 4 5 6 7 Test items High temperature storage test Low temperature storage test High temperature and high humidity operating test High temperature operating test Low temperature operating test Electro static discharge test Shock tset Ta=+70 Ta=20 Tp=+40 , 95%RH Tp=+60 Tp=10 Test conditions 240h 240h 240h 240h 240h (1 time for each terminals) 980 m/s2, 6 ms (JIS C0041, A-7 Condition C) 8 Vibration test Frequency range: 10Hz5510Hz Stroke: 1.5 mm Sweep: 10Hz55Hz X,Y,Z 2 hours for each direction (total 6 hours) (JIS C0040,A10 Condition A) 9 10 Heat shock test Point activation test (Touch panel) Ta=20+70 / 5 cycles (1h) (1h) Hit it 1,000,000 times with a silicon rubber of R8 HS 60. Hitting force :2.45N(250gf) Hitting speed : 3 times per second 11 Writing friction resistance test (Touch panel) Slide Pen 100,000 times under following conditions: Pen : 0.8Rmm Polyacetal stylus Load : 2.45N(250gf) Speed : 3 strokes per second Stroke : 35mm Testing apparatus : shown in Fig.3 X,Y,Z 3 times for each direction
(But no condensation of dew)
200V200pF(0) to Terminals(Contact)
Motor
Weight 2.45N(250gf) Stroke 35mm
Touch Panel Fig.3
LCP-06008A-19
NoteTa = Ambient temperature, Tp = Panel temperature Check items Test No.19 In the standard condition, there shall be no practical problems that may affect the display function. Test No.10No.11 The measurements after the tests are satisfied (11)-Table 11 (Touch panel characteristics) (16) Others 16-1)Indication of lot number The lot number is shown on a label. Attached location is shown in Fig.1 (Outline Dimensions). 16-2) Used Regulation of Chemical Substances Breaking Ozone Stratum Substances with the object of regulating: CFCS, Carbon tetrachloride, Halon 1,1,1-Trichloro ethane (Methyl chloroform) (a) This LCD module, Constructed part and Parts don't contain the above substances. (b) This LCD module, Constructed part and Parts don't contain the above substances in processes of manufacture. 16-3) If some problems arise about mentioned items in this document and other items, the user of the TFT-LCD module and Sharp will cooperate and make efforts to solve the problems with mutual respect and good will. (17)Forwarding form (fig4) a) Piling number of cartons : 8 b) Package quality in one cartons : 100 pcs c) Carton size : 575 mm x 360 mm x 225 mm d) Total mass of 1 carton filled with full modules : 8,600 g Conditions for storage Environment (1)Temperature (2)Humidity (3)Atmosphere (4)Period : 040 : 60%RH or less (at 40) No dew condensation at low temperature and high humidity. : Harmful gas, such as acid or alkali which bites electronic components and/or wires, must not be detected. : about 3 months electrostatic charges, please control the room humidity over 50%RH and open the package taking sufficient countermeasures against electrostatic charges, such as earth, etc. (5)Opening of the package : In order to prevent the LCD module from breakdown by
LCP-00000-1
NOTICE
This publication is the proprietary of SHARP and is copyrighted, with all rights reserved. Under the copyright laws, no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical for any purpose, in whole or in part, without the express written permission of SHARP Express written permission is also required before any use of this publication may be made by a third party.
The application circuit examples in this publication are provided to explain the representative applications of SHARP's devices and are not intended to guarantee any circuit design or permit any industrial property right or other rights to be executed. SHARP takes no responsibility for any problems related to any industrial property right or a third party resulting from the use of SHARP's devices, except for those resulting directly from device manufacturing processes.
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP's device.
SHARP reserves the right to make changes in the specifications, characteristics, data, materials, structures and other contents described herein at any time without notice in order to improve design or reliability. Contact SHARP in order to obtain the latest specification sheets before using any SHARP's device. Manufacturing locations are also subject to change without notice.
Observe the following points when using any device in this publication. SHARP takes no responsibility for damage caused by improper use of the devices.
The appropriate design measures should be taken to ensure reliability and safety when SHARP's devices are used for equipment such as: * Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc.) * Traffic signals * Gas leakage sensor breakers * Alarm equipment * Various safety devices etc. SHARP's devices shall not be used for equipment that requires extremely high level of reliability, such as: * Military and space applications * Medical equipment for life support * Nuclear power control equipment
Contact a SHARP representative, in advance, when intending to use SHARP's devices for any "specific" applications other than those recommended by SHARP.
Contact and consult with a SHARP representative if there are any questions about the contents of this publication.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Suggested applications (if any) are for standard use; See Important Restrictions for limitations on special applications. See Limited Warranty for SHARP's product warranty. The Limited Warranty is in lieu, and exclusive of, all other warranties, express or implied. ALL EXPRESS AND IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR USE AND FITNESS FOR A PARTICULAR PURPOSE, ARE SPECIFICALLY EXCLUDED. In no event will SHARP be liable, or in any way responsible, for any incidental or consequential economic or property damage.
NORTH AMERICA
EUROPE
JAPAN
SHARP Microelectronics of the Americas 5700 NW Pacific Rim Blvd. Camas, WA 98607, U.S.A. Phone: (1) 360-834-2500 Fax: (1) 360-834-8903 Fast Info: (1) 800-833-9437 www.sharpsma.com
SHARP Microelectronics Europe Division of Sharp Electronics (Europe) GmbH Sonninstrasse 3 20097 Hamburg, Germany Phone: (49) 40-2376-2286 Fax: (49) 40-2376-2232 www.sharpsme.com
SINGAPORE
SHARP Corporation Electronic Components & Devices 22-22 Nagaike-cho, Abeno-Ku Osaka 545-8522, Japan Phone: (81) 6-6621-1221 Fax: (81) 6117-725300/6117-725301 www.sharp-world.com
TAIWAN
KOREA
SHARP Electronic Components (Taiwan) Corporation 8F-A, No. 16, Sec. 4, Nanking E. Rd. Taipei, Taiwan, Republic of China Phone: (886) 2-2577-7341 Fax: (886) 2-2577-7326/2-2577-7328
SHARP Electronics (Singapore) PTE., Ltd. 438A, Alexandra Road, #05-01/02 Alexandra Technopark, Singapore 119967 Phone: (65) 271-3566 Fax: (65) 271-3855
SHARP Electronic Components (Korea) Corporation RM 501 Geosung B/D, 541 Dohwa-dong, Mapo-ku Seoul 121-701, Korea Phone: (82) 2-711-5813 ~ 8 Fax: (82) 2-711-5819
CHINA
HONG KONG
SHARP Microelectronics of China (Shanghai) Co., Ltd. 28 Xin Jin Qiao Road King Tower 16F Pudong Shanghai, 201206 P.R. China Phone: (86) 21-5854-7710/21-5834-6056 Fax: (86) 21-5854-4340/21-5834-6057 Head Office: No. 360, Bashen Road, Xin Development Bldg. 22 Waigaoqiao Free Trade Zone Shanghai 200131 P.R. China Email: smc@china.global.sharp.co.jp
SHARP-ROXY (Hong Kong) Ltd. 3rd Business Division, 17/F, Admiralty Centre, Tower 1 18 Harcourt Road, Hong Kong Phone: (852) 28229311 Fax: (852) 28660779 www.sharp.com.hk Shenzhen Representative Office: Room 13B1, Tower C, Electronics Science & Technology Building Shen Nan Zhong Road Shenzhen, P.R. China Phone: (86) 755-3273731 Fax: (86) 755-3273735


▲Up To Search▲   

 
Price & Availability of LS037V7DW01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X